Process Mapping Logo

Process Mapping - Forums

Sharing 19 years of knowledge and experience

 
Metastorm BPM forums
Sign up Latest Topics
 
 
 


Reply
  Author   Comment  
Jerome

Avatar / Picture

Guru
Registered:
Posts: 5,507
Reply with quote  #1 

Connection Parameters Changed By Upgrade

Last edited: 22 Feb 2005


The information in this article applies to product: e-Work 6.x

Issue

  • After upgrading, the Engine doesn't start because the e-Work ODBC DSN has been changed by the upgrade.

Resolution

  • Information that the user inputs during the initial installation of e-Work is stored in this registry key:
    HKEY_LOCAL_MACHINE\SOFTWARE\Metastorm\e-work\InstallInfo.

    These values are used for any subsequent upgrades or hotfix installs.

    Thus, if any parameters (DSN name, DB user name, Engine service user, etc.) are changed after the initial installation of e-Work, the appropriate changes should be made                                         to the values in this registry key. Otherwise, the correct values will be overwritten                                         by an upgrade, and will have to be changed manually where necessary.

Keywords: kb494


__________________
Post an example, and we will have a much better idea what the problem is. In about 90% of posts, the problem is one of communication. Examples bridge that gap.