Process Mapping Logo

Process Mapping - Forums

Sharing 19 years of knowledge and experience

 
Metastorm BPM forums
Sign up Latest Topics
 
 
 


Reply
  Author   Comment  
Jerome

Avatar / Picture

Guru
Registered:
Posts: 5,507
Reply with quote  #1 

Object Reference Not Set To an Instance of an Object

Created: 14 Apr 2005
                                Last edited: 31 Aug 2005


The information in this article applies to product: e-Work 6.x

Issue

  • The message 'Object reference not set to an instance of an object' is displayed in the web browser.

Resolution

  • If the e-Work web components are running on Windows Server 2003, open Internet Information Services (IIS) Manager and drill down to Default App Pool. Right-click and select 'Recycle.' If this resolves the immediate problem but the problem recurs, right-click on Default App Pool and select 'Properties.' On the 'Recycling' tab, configure the server to recycle                                         worker processes more frequently. For example, you might set the processes to recycle daily at noon and midnight or set them to recycle every 35000 requests.
  •                                 The design of the e-Work 6.6.2 web components should resolve this issue.                                

Keywords: kb539


__________________
Post an example, and we will have a much better idea what the problem is. In about 90% of posts, the problem is one of communication. Examples bridge that gap.